WellReport Well records, made clear
95 Tomilson Ln  ·  Well Record ID 7407118
Map
New to well records?

Well Record ID 7407118

95 Tomilson Ln

Lot 53, Concession 2  ·  Ameliasburg Township  ·  Prince Edward

The address the driller recorded when the well was constructed. It may differ from today's address. "Lot 53, Concession 2" is an older land reference used before street addresses.
Well tag
A325225

The number on the metal tag attached to the wellhead.

This page is based on one provincial well record filed near this location. The same property may have more than one.This page shows one well record. The property may have others.

See this well and its neighbours on the map →

Well log diagram

Soil and rock layers, from the surface down, with the colours recorded.

Ground layers as written in the record, top to bottom:

Depth, feet (metres) Description 2 ft (0.6 m) 22.5 ft (6.9 m) Topsoil - brown Limestone - grey Legend Topsoil Limestone / Dolomite Surface seal Casing
Flow rate
Not shown 1
The rate the driller recommended running a pump at, written on the well record when the well was constructed. Not a measurement of today's flow. GPM is imperial gallons per minute; LPM is litres per minute.
Well Depth
23 ft
6.9 m
How far down the hole goes, from the surface to the bottom.
Drilled into
Bedrock
solid rock
Whether the hole ends in solid rock or the loose material above it.
Location accuracy
30 m - 100 m
how far the map dot could be off
The province's rating of how far the map dot may be from the well.
Year drilled
2021
 
The year the driller finished the well.
Status of well
Water Supply
Well use: Domestic

Water

Water levelNot recorded
How far down the water sits in the well with the pump off, measured from the surface. It can rise and fall with the seasons.
Water found at depth
2.1 m (7 ft) - Fresh, Untested
4 m (13 ft) - Fresh, Untested
4.6 m (15 ft) - Fresh, Untested
Depths where the driller found water, and the kind of water the driller marked on the form. 'Untested' means the driller did not check what kind of water it was.
Is the well flowingNo
If the groundwater level is above the ground surface, water can flow out on its own, without a pump.
The pump test on this record
The driller pumped this well for 1 hour.
A controlled test the driller ran when the well was constructed. These results do not show today's flow.
Water level before pumpingNot recorded
How far down the water sat in the well before the test began. The same resting level shown above.
Water level at the end of the test2.3 m (8 ft) below ground
How far down the water stood when the test ended, after the pumping drew it down.
How long the pumping test ran1 hour
How long the test lasted.

Construction

Drilling methodDigging, Other
How the hole was made.
CompletionNot recorded
How the bottom of the well was finished to let water in.
Surface sealNon toxic caulking, 0 - 10 ft (0 - 3 m)
Material around the outside of the casing, near the ground. It helps keep surface water out.

Casing is the pipe lining the hole. It keeps the hole open and keeps loose ground and surface water out.

CasingDepthDiameter
Concrete 0 - 22.5 ft (0 - 6.9 m) 36 in (91 cm)

Screen details: Not recorded

About the numbers on this page

  1. The provincial record lists a recommended pump rate of 10 GPM and a test rate of 150 GPM for this well's pump test - two rates more than ten times apart - so this page does not show a flow rate.

The full record

Opens the province's copy. Not every well has one.

Printing is not available yet.