WellReport Well records, made clear
Lot 23, MT 3  ·  Well Record ID 5305149
Map
New to well records?

Well Record ID 5305149

Lot 23, MT 3

Hallowell Township  ·  Prince Edward

An older land reference, used before street addresses.

This page is based on one provincial well record filed near this location. The same property may have more than one.This page shows one well record. The property may have others.

See this well and its neighbours on the map →

Well log diagram

Soil and rock layers, from the surface down, with the colours recorded.

Ground layers as written in the record, top to bottom:

Depth, feet (metres) Description 6 ft (1.8 m) 10 ft (3.0 m) 20 ft (6.1 m) 30 ft (9.1 m) 40 ft (12.2 m) 50 ft (15.2 m) 65 ft (19.8 m) 100 ft (30.5 m) Sandstone, Soft - brown Limestone, Porous, Soft - grey Limestone, Hard - grey Limestone, Soft - grey Limestone, Hard - grey Limestone, Soft - grey Limestone, Hard - grey Legend Limestone / Dolomite Sandstone Abandonment plugging Water level Break mark
Flow rate
Not shown 1
The rate the driller recommended running a pump at, written on the well record when the well was constructed. Not a measurement of today's flow. GPM is imperial gallons per minute; LPM is litres per minute.
Well Depth
100 ft
30.5 m
How far down the hole goes, from the surface to the bottom.
Drilled into
Bedrock
solid rock
Whether the hole ends in solid rock or the loose material above it.
Location accuracy
10 - 30 m
how far the map dot could be off
The province's rating of how far the map dot may be from the well.
Year drilled
1989
 
The year the driller finished the well.
Status of well
Abandoned - not enough water
Well use: Domestic
"Abandoned" is the province's word for a well that is no longer in use. It does not by itself say the hole was filled in. Where plugging was recorded, it shows below and on the scanned record.

Water

Water level3.0 m (10 ft) below ground
How far down the water sits in the well with the pump off, measured from the surface. It can rise and fall with the seasons.
Water found at depth
3 m (10 ft) - Fresh
Depths where the driller found water, and the kind of water the driller marked on the form. 'Untested' means the driller did not check what kind of water it was.
Is the well flowingNo
If the groundwater level is above the ground surface, water can flow out on its own, without a pump.
The pump test on this record
The driller pumped this well for 1 hour 20 minutes.
A controlled test the driller ran when the well was constructed. These results do not show today's flow.
Water level before pumping3.0 m (10 ft) below ground
How far down the water sat in the well before the test began. The same resting level shown above.
Water level at the end of the test30.2 m (99 ft) below ground
How far down the water stood when the test ended, after the pumping drew it down.
How long the pumping test ran1 hour 20 minutes
How long the test lasted.

Construction

Drilling methodCable Tool
How the hole was made.
CompletionNot recorded
How the bottom of the well was finished to let water in.
Surface sealNot recorded
Material around the outside of the casing, near the ground. It helps keep surface water out.
Abandonment plugging0 - 10 ft (0 - 3 m)
Material placed to close the well for good.

Casing is the pipe lining the hole. It keeps the hole open and keeps loose ground and surface water out.

CasingDepthDiameter
Not recorded - 8 in (20 cm)
Not recorded - 6 in (15 cm)
Not recorded - 6 in (15 cm)

Screen details: Not recorded

About the numbers on this page

  1. The provincial record lists a recommended pump rate of 20 GPM and a test rate of 1 GPM for this well's pump test - two rates more than ten times apart - so this page does not show a flow rate.

The full record

Opens the province's copy. Not every well has one.

Printing is not available yet.