WellReport Well records, made clear
Hallowell Township  ·  Well Record ID 5303909
Map
New to well records?

Well Record ID 5303909

Hallowell Township

TI  ·  Prince Edward

The record names only the area, not a street address. The land reference is filed as "TI".

This page is based on one provincial well record filed near this location. The same property may have more than one.This page shows one well record. The property may have others.

See this well and its neighbours on the map →

Well log diagram

Soil and rock layers, from the surface down, with the colours recorded.

Ground layers as written in the record, top to bottom:

Depth, feet (metres) Description 4 ft (1.2 m) 8 ft (2.4 m) 19 ft (5.8 m) 25 ft (7.6 m) 49 ft (14.9 m) 59 ft (18 m) 72 ft (21.9 m) Topsoil, Packed - brown Hardpan, Boulders, Hard - brown Hardpan, Stones, Packed - grey Hardpan, Hard, Packed - grey Hardpan, Stones, Hard - grey Limestone, Hard - grey Legend Topsoil Till / Hardpan Limestone / Dolomite Casing Open hole Water level
Flow rate
30 GPM
136.4 LPM
The rate the driller recommended running a pump at, written on the well record when the well was constructed. Not a measurement of today's flow. GPM is imperial gallons per minute; LPM is litres per minute.
Well Depth
72 ft
21.9 m
How far down the hole goes, from the surface to the bottom.
Drilled into
Bedrock
solid rock
Whether the hole ends in solid rock or the loose material above it.
Location accuracy
30 m - 100 m
how far the map dot could be off
The province's rating of how far the map dot may be from the well.
Year drilled
1979
 
The year the driller finished the well.
Status of well
Water Supply
Well use: Domestic

Water

Water level7.6 m (25 ft) below ground
How far down the water sits in the well with the pump off, measured from the surface. It can rise and fall with the seasons.
Water found at depth
20.7 m (68 ft) - Fresh
Depths where the driller found water, and the kind of water the driller marked on the form. 'Untested' means the driller did not check what kind of water it was.
Is the well flowingNo
If the groundwater level is above the ground surface, water can flow out on its own, without a pump.
The pump test on this record
The driller pumped this well at 30 GPM (136.4 LPM) for 1 hour 30 minutes.
A controlled test the driller ran when the well was constructed. These results do not show today's flow.
Water level before pumping7.6 m (25 ft) below ground
How far down the water sat in the well before the test began. The same resting level shown above.
Water level at the end of the test12.2 m (40 ft) below ground
How far down the water stood when the test ended, after the pumping drew it down.
How long the pumping test ran1 hour 30 minutes
How long the test lasted.

Construction

Drilling methodCable Tool
How the hole was made.
CompletionOpen Hole
How the bottom of the well was finished to let water in.
Surface sealNot recorded
Material around the outside of the casing, near the ground. It helps keep surface water out.

Casing is the pipe lining the hole. It keeps the hole open and keeps loose ground and surface water out.

CasingDepthDiameter
Steel 0 - 61 ft (0 - 18.6 m) 6 in (15 cm)
Open Hole 61 - 72 ft (18.6 - 21.9 m) 6 in (15 cm)

Screen details: Not recorded

The full record

Opens the province's copy. Not every well has one.

Printing is not available yet.